SPECIFICATION Pumping unit VX136 - 105Q 7.5 kW VX136 - 140Q 11 kW VX136 - 210Q 15 kW VX186 - 184Q 22 kW VX186 - 260Q 30 kW No. of pumping units 1 1 1 1 1 Capacity up to 60 m³ / h 80 m³ / h 110 m³ / h 160 m³ / h 300 m³ / h Vacuum range 0 to -0.60 bar (normal operation) 0 to -0.60 bar (normal operation) 0 to -0.60 bar (normal operation) 0 to -0.60 bar (normal operation) 0 to -0.60 bar (normal operation) Differential pressure max. Power consumption at Δp=0.6 bar Control 2.0 bar 2.5 bar 3.0 bar 3.0 bar 2.0 bar 4.2 kW 5.4 kW 6.3 kW 9.6 kW 17.4 kW Integrated PLC control incl. control elements & indicators 10,1″ touchscreen HMI-interface with system visualisation. Multilingual plain text process data & fault notification Voltage: 3-400 V, 50 Hz Cable grommet: max. Ø25 mm² Pipe system SP-pump connectors incl. ball type back flow preventer and isolation valves Connector inlet Connector outlet Common base plate Main dimensions L x W x H approx. DN 100 - axial restraint pipe coupling DN 100 - axial restraint pipe coupling DN 100 - axial restraint pipe coupling DN 100 - axial restraint pipe coupling DN 150 - axial restraint pipe coupling DN 150 - axial restraint pipe coupling DN 150 - axial restraint pipe coupling DN 150 - axial restraint pipe coupling DN 200 - axial restraint pipe coupling DN 200 - axial restraint pipe coupling Heavy duty mild steel galv. construction 1,750 x 1,100 x 1,900 1,750 x 1,100 x 1,900 2,250 x 1,100 x 1,900 2,250 x 1,100 x 1,900 2,250 x 1,100 x 1,900 Weight approx. 1,000 kg 1,150 kg 1,350 kg 1,500 kg 1,650 kg Ambient temperatures Ambient conditions +5 to +40 °C +5 to +40 °C +5 to +40 °C +5 to +40 °C +5 to +40 °C Indoor, moderate Indoor, moderate Indoor, moderate Indoor, moderate Indoor, moderate